Zum Inhalt springen

METPOINT® FLM

Sensor technology for flow measurement

One compressor in three runs solely to compensate for air losses – unnecessary compressed air consumption whose costs are largely avoidable. Precise measurement of the current flow rate is an effective solution. It forms the basis for numerous important analyses, documentation and decisions. With the METPOINT FLM SF13 and SF53, BEKO TECHNOLOGIES offers precise monitoring at the point of use.

Pipe diameter

¼ to 10 inches

Operating pressure

up to 16 bar

Supply

18 to 36 VDC

Measuring principle

calorimetric

Optimise compressed air consumption in your company

If you know your compressed air consumption, you can reduce it in a targeted way. The METPOINT FLM measures the flow rate directly in the compressed air line using the calorimetric measuring principle.

Flow meter with display

The display and configuration menu allow all measured values to be shown and sensor settings to be made

Flow meter with LED

The more economical LED version indicates when a new calibration is due (annually). Please note: the sensor can only be configured during production or later using the BDL data logger

How flow measurement works

For flow measurement, two temperature sensors are placed one behind the other in the direction of flow of the compressed air. The first sensor records the current process temperature of the compressed air, while the second sensor is heated electrically so that it is always 40 kelvin warmer than the first.

As the volume or mass flow increases, the sensors cool down, causing the electric heating of the second sensor to counteract this. The electrical energy required to maintain this temperature difference is directly proportional to the flow rate. This means that as the flow rate rises, the required heating power also rises, and this value is then converted into corresponding measurement data.

Benefits of METPOINT® FLM flow measurement

Identify savings potential

  • accurate monitoring of compressed air consumption
  • shows flow rate, consumption and flow velocity
  • provides the basis for intelligent energy management
  • basis for economical system design and determining leakage volumes

Practical and precise

  • Plug & Play
  • installation and removal possible under pressure
  • suitable for pipe diameters from ¼’’ to 10’’
  • calibration date shown on the integrated display or service LED
  • ideal for compressed air technology thanks to the calorimetric measuring principle

Technical data METPOINT® FLM

Measuring principleCalorimetric measurement
Measured variablesStandard settings: m³/h, m³ and m/s
DisplayService LED or TFT display 1.8"
Accuracy± 1.5 % of measured value ± 0.3 % of full scale
Power supply18 to 36 VDC
Output signal4 … 20 mA, RS485 (MODBUS RTU)
Pulse output1 pulse per m³ or per litre, volt-free pulse output
Operating pressureup to 16 bar, optionally up to 50 bar with SF53
Technical data METPOINT® FLM

* Further technical data can be found in the product information in the download section below…

Calibration service for your METPOINT® FLM

Transducers and transmitters are frequently exposed to mechanical stress and temperature fluctuations. This can lead to a decrease in the measuring accuracy of the sensors and cause what is known as “drift”, which distorts measurement results and can therefore impair production or product quality.

BEKO TECHNOLOGIES offers a comprehensive range of calibration services for flow sensors, pressure dew point transmitters, pressure transmitters and analysers. These calibrations are carried out according to a specified BEKO TECHNOLOGIES procedure and correspond to an ISO calibration. ISO calibrations are comparative measurements of external test items against in-house reference instruments that are traceable to national standards. All calibration procedures meet the requirements of the DIN EN ISO 9001 quality standard.

Frequently asked questions

What do I use the METPOINT FLM for?

It measures the flow rate at the point of use. This lets you monitor compressed air consumption, identify savings potential and determine leakage volumes.

How does the METPOINT FLM measure?

Two temperature sensors sit one behind the other in the flow. The second is kept constantly 40 kelvin warmer than the first. The heating power required for this is proportional to the flow rate.

Which measured variables does the sensor display?

As standard, flow rate in m³/h, consumption in m³ and flow velocity in m/s.

Which pipe sizes is the METPOINT FLM suitable for?

For pipe diameters from ¼ to 10 inches. The operating pressure can be up to 16 bar, or optionally up to 50 bar with the SF53.

Can I install the sensor without shutting down the system?

Yes. Installation and removal are possible under pressure, and the sensor is Plug & Play.

What is the difference between the display and LED versions?

With the display, you show all measured values and make settings directly on the device. The more economical LED version only indicates when a new calibration is due. It is configured during production or later via the BDL data logger.

How accurate is the METPOINT FLM?

The accuracy is ± 1.5 % of measured value ± 0.3 % of full scale.

How do I connect the sensor to my control system?

Via the 4 … 20 mA output, via RS485 (MODBUS RTU) or via the volt-free pulse output with one pulse per m³ or per litre.

How often does the sensor need to be calibrated?

Annually. BEKO TECHNOLOGIES calibrates according to a defined procedure that corresponds to an ISO calibration and is traceable to national standards.

Who can help me choose the measurement technology?

We can. We advise you on choosing the right measurement technology for your application. Call us or write to us.

The right measurement technology for your application?

Let us advise you to find the best measurement technology for your needs and application.

Download

Your quote in three steps

New system, spare parts and service, or a rental or used unit: tell us what you need. We will get back to you personally with a suitable quote, brand-independent and tailored to your application.

Your request
Topic

Your details

Your enquiry

Fields marked with * are required. We only use your details to process your enquiry; more in our privacy policy.