CLEARPOINT® H
Compressed air heater for optimum operating conditions
Condensate and icing significantly impair the process reliability and efficiency of compressed air systems. When compressed air cools, condensate forms in the piping network, leading to increased wear, malfunctions and inconsistent product quality. This is where the CLEARPOINT® H compressed air heater provides a solution.
Outlet temperature
+30 to +60 °C
Flow rate
max. 100 m³/h
Operating pressure
max. 16 bar
Inlet temperature
+2 to +50 °C
Greater process reliability and optimum operating conditions
Rapid expansion of compressed air produces expansion cold, which can cause valves and control fittings to ice up and jeopardise process reliability. In applications such as breathing air and dental technology, the cold can also reduce comfort. The CLEARPOINT compressed air heater warms the compressed air to the optimum application-specific temperature – adjustable between +30 and +60 °C – creating the best conditions at the point of use.
Outlet temperature of the compressed air as a function of flow rate at an inlet temperature of +20 °C.
At different inlet temperatures, the temperature curve shifts accordingly. The maximum outlet temperature is limited to 60 °C.

Benefits of the CLEARPOINT® H compressed air heater
Safety
Protects compressed air consumers by reducing relative humidity
Cost-effectiveness
Speeds up manufacturing processes by heating the compressed air
Optimum operating conditions
High functional and operational reliability thanks to an encapsulated, corrosion-free stainless steel heating cartridge
Technical data
| Max. operating pressure | 16 bar [ g ] |
| Flow rate at 7 bar | max. 50 m³/h (S040TWC) max. 100 m³/h (S050TWC) |
| Differential pressure | S040 at 50 m³/h: <0.15 bar S050 at 100 m³/h: <0.2 bar |
| Inlet temperature / ambient temperature | +2 … +50 °C |
| Compressed air outlet temperature | adjustable from +30 to +60 °C |
| Internal safety cut-out temperature | +84 °C |
| Max. housing temperature | +80 °C |
Further information can be found in the data sheet.
Frequently asked questions
Why do you need a compressed air heater?
Rapid expansion produces expansion cold that can freeze valves and control fittings. The CLEARPOINT H warms the compressed air and so protects process reliability.
To what temperature does the CLEARPOINT H heat the compressed air?
The outlet temperature is adjustable between +30 and +60 °C. It cannot go higher than 60 °C.
What flow rates can the CLEARPOINT H handle?
At 7 bar, a maximum of 50 m³/h with the S040TWC and a maximum of 100 m³/h with the S050TWC.
How high is the pressure loss?
For the S040 below 0.15 bar at 50 m³/h, for the S050 below 0.2 bar at 100 m³/h.
In which applications does the heater make sense?
Wherever cold is a problem at the point of use, for example in breathing air and dental technology. Warm compressed air also speeds up manufacturing processes.
How does the heater protect compressed air consumers?
Heating lowers the relative humidity of the compressed air. This protects the consumers.
Is the CLEARPOINT H protected against overheating?
Yes. The internal safety cut-out trips at +84 °C, and the housing temperature is no more than +80 °C.
What ambient conditions are permissible?
Inlet and ambient temperature must be between +2 and +50 °C, and operating pressure no more than 16 bar.
Who helps me choose?
We can. We review your application and select the right model with you. Call us or write to us.

Need support?
Do you need support with your process technology application? Let us advise you to find the optimum model for your needs.