Hankison heatless dryers offer an air flow of 90 m³/h to 9,000 m³/h. They feature a twin-tower design filled with high-quality activated alumina. These models are available with three different, application-specific control systems designed to meet industrial requirements for economy and performance efficiently.

Flow rate

90 to 9,000 m³/h

Pressure dew point

down to −70 °C

Pressure

10 to 16 bar

Connection

¾″ to DN 150

HHL Series desiccant dryers: reliable solutions for industrial compressed air requirements

Hankison HHL Series heatless regenerative desiccant dryers are filled with high-quality activated alumina and are available with various application-specific control systems to meet industrial requirements for economy and performance. These dryers deliver constant outlet pressure dew points down to -70 °C.

Standard instrumentation includes:

  • Pressure gauges on both towers and on the purge system
  • A moisture indicator that warns of an elevated dew point
  • A throttle valve for precise adjustment of the purge pressure
  • Inlet and outlet filters included as standard

HHL Series models from HHL 91 to HHL 901 are rated up to 16 bar as standard, while models HHL 1051 to HHL 9001 offer 10 bar as standard, with a 16 bar option.

Controller options:

  • Level 1 controller: simple and functional, it provides traditional heatless drying with timer-based control, ideal for applications at full or near-full load. Automatic, timed regeneration cycles of the beds ensure constant performance and are cost-effective.
  • LX controller: an advanced PLC controller with a PDP sensor and an energy-saving function, offering additional efficiency and convenient monitoring.

These dryers are ideal for applications requiring high air quality with minimal energy consumption, and offer both reliability and advanced technology to meet your specific industrial needs.

Efficient and reliable desiccant dryers for industrial applications

  • Wide air flow range: HHL dryers offer an air flow of 90 m³/h to 9,000 m³/h, making them suitable for a wide variety of industrial applications.
  • High-quality desiccant: equipped with activated alumina in a twin-tower design, these dryers ensure efficient moisture removal and stable pressure dew points down to -70°C.
  • Application-specific control systems: available with various control options, including the simple Level 1 controller for timed regeneration and the advanced LX controller with PDP sensor and energy-saving function, to meet specific industrial requirements.
  • Standard instrumentation: with pressure gauges on both towers to monitor system pressure and a moisture indicator that warns of an elevated dew point, these dryers provide precise control and reliable alerts.
  • Throttle valve for precise adjustment: allows fine tuning of the purge pressure, resulting in improved efficiency and performance.
  • Inlet and outlet filters as standard: these components are an integral part of the dryers and protect the installation against incoming and outgoing contaminants, improving the overall quality of the compressed air.
  • High pressure ratings: depending on the model, standard pressures range from 10 bar to 16 bar, making them suitable for high-pressure applications.
  • Energy and cost savings: the automatic, timed regeneration cycles minimise energy consumption and reduce operating costs while ensuring constant performance.
  • Versatile pressure settings: the ability to adjust pressure settings as required without major modifications increases the operational flexibility of the dryers.

Specifications

ModelAir flowConnectionElectrical connectionsPre-filterAfter-filter
m3/hV/Hz
HHL 91903/4”95-240/50F06-B-HFF06-B-PF
HHL 1411403/4”F07-B-HFF07-B-PF
HHL 2712701“F08-B-HFF08-B-PF
HHL 3513501 1/2”F10-B-HFF10-B-PF
HHL 5215201 1/2”F11-B-HFF11-B-PF
HHL 6816801 1/2”F12-B-HFF12-B-PF
HHL 9019002”F14-B-HFF14-B-PF
HHL 105110502 1/2“95-240/50F14-B-HFF14-B-PF
HHL 135113502 1/2“F15-B-HFF15-B-PF
HHL 165116503”F16-B-HFF16-B-PF
HHL 195119503”F17-B-HFF17-B-PF
HHL 23512350DIN 100HF5-60HF6-60
HHL 27012700DIN 100HF5-60HF6-60
HHL 36013600DIN 100HF5-64HF6-64
HHL 52015200DN 150HF5-68HF6-68
HHL 71017100DN 150HF5-72HF6-72
HHL 90019000DN 150HF5-76HF6-76

1 Inlet flows are determined in accordance with ISO 7183 (based on 1 bar (abs), 0 % of 7 bar (g) working pressure and an inlet temperature of 35 °C (PDP -40 °C) or an inlet temperature of 30 °C PDP -70 °C C

2 Average purge flow is the total quantity of air, averaged over the cycle time, used to purge and repressurise off-stream towers. Maximum purge flow is the flow rate through the off-stream tower during the part of the cycle in which the purge/repressurisation valve is open.

Frequently asked questions

What air flows does the Hankison HHL Series cover?

An air flow of 90 m³/h for the HHL 91 up to 9,000 m³/h for the HHL 9001.

How does the HHL dryer work?

It works without heat using two towers filled with activated alumina. The beds are regenerated in automatic, timed cycles.

What pressure dew point does the HHL Series achieve?

Constant outlet pressure dew points down to −70 °C.

What operating pressure is the series designed for?

Models HHL 91 to HHL 901 are rated up to 16 bar as standard. Models HHL 1051 to HHL 9001 are rated 10 bar as standard, 16 bar as an option.

Which controllers are available?

The Level 1 controller regenerates on a timed basis and is suitable for applications at full or near-full load. The LX controller is a PLC control with PDP sensor and energy-saving function.

What is fitted as standard?

Pressure gauges on both towers and on the purge system, a moisture indicator that warns of an elevated dew point, a throttle valve for adjusting the purge pressure, and inlet and outlet filters.

What connection sizes are available?

Depending on the model, from ¾″ for the HHL 91 to DN 150 for the largest models.

Which filters belong to the individual models?

In the specification table, each model is assigned a matching pre-filter and after-filter, for example F06-B-HF and F06-B-PF for the HHL 91.

Who can help me choose the right model?

We can. We clarify the flow rate, pressure dew point and compressor output with you and select the right model. Call us or write to us.

Which dryer suits your application?

There are various pressure dew points and flow rates, which vary depending on compressor output and field of application and must be taken into account. Let us advise you to find the optimum model for your needs.

Your quote in three steps

New system, spare parts and service, or a rental or used unit: tell us what you need. We will get back to you personally with a suitable quote, brand-independent and tailored to your application.

Your request
Topic

Your details

Your enquiry

Fields marked with * are required. We only use your details to process your enquiry; more in our privacy policy.