Zum Inhalt springen

METPOINT® UD01/UD02

Plug-on displays

In many production and treatment processes, real-time data and on-site information are required in order to assess the quality of the compressed air immediately and make adjustments if necessary. For this purpose, the display is integrated between the transmitter and the data line. The METPOINT UD01 and UD02 plug-on displays visualise measurement data such as pressure or dew point directly at the transmitter, which is exactly where this data is generated.

Input

4 to 20 mA, 2-wire

Operation

two buttons

Alarm contacts

two (UD02)

Efficient data display directly on the transmitter

The plug-on displays are compatible with all transmitters that have a 4 … 20 mA / 2-wire analogue output. A user-friendly menu system operated by two buttons allows the displays to be programmed flexibly. User settings such as measuring range and alarm values are retained even in the event of a power failure or when switching to other sensors. Range overruns are indicated both visually (LED) and, on the UD02, by the 4-20 mA value.

Precise monitoring with alarm function

The UD02 plug-on display is equipped with two integrated alarm contacts that allow simple visual or acoustic signalling of pre-alarms and main alarms. When an alarm is triggered, the corresponding LEDs next to the digital display light up and the associated switching contacts are activated. Various unit labels are included in the scope of delivery so that the display can be customised.

* Further technical data can be found in the product information in the download section below…

Frequently asked questions

What do I need a METPOINT UD01 or UD02 plug-on display for?

It shows readings such as pressure or dew point directly at the transmitter. This lets you assess the compressed air quality on site and react immediately.

How is the display installed?

It is plugged in between the transmitter and the data line.

Which transmitters is the display compatible with?

With all transmitters that have a 4 … 20 mA analogue output in 2-wire technology.

What is the difference between the UD01 and UD02?

The UD02 has two integrated alarm contacts for pre-alarm and main alarm. In the event of an alarm, the corresponding LEDs light up and the switching contacts are activated.

How do I program the display?

Via a menu with two buttons. Measuring range and alarm values are retained even in the event of a power failure or when switching to another sensor.

How does the display indicate a range overrun?

Via an LED. On the UD02, additionally via the 4-20 mA value.

Can I change the unit displayed?

Yes. Various unit labels are included in the scope of delivery.

Who helps me choose the right display?

We can. We advise you on choosing the right measurement technology for your application. Call us or write to us.

The right measurement technology for your application?

Let us advise you to find the best measurement technology for your needs and application.

Download