Why intelligent compressed air treatment saves more energy than ever today
For many Swiss manufacturers, energy costs are among the largest ongoing expenses. Accordingly, when investing, companies often make sure to choose an energy-efficient screw compressor. One area, however, is often overlooked: compressed air treatment.
In many companies, the refrigeration dryer in particular runs around the clock – regardless of whether a lot or very little compressed air is needed at the time. This leads to unnecessary electricity consumption and increases operating costs year after year.
With the HDI-E series, Hankison has developed a cycling refrigeration dryer that solves precisely this problem. Thanks to intelligent thermal storage and demand-based control, the refrigeration compressor only runs when cooling capacity is actually needed. Companies with strongly fluctuating compressed air demand in particular benefit from considerably lower energy costs as a result.
In this article, you will learn how refrigeration dryers work, why conventional systems often use energy unnecessarily and why the Hankison HDI-E series is an economically attractive solution for many Swiss manufacturers.
Why does compressed air need to be dried at all?
Atmospheric air always contains moisture. When this air is compressed in the compressor, the concentration of water vapour rises considerably. If the compressed air then cools down again in pipes or machines, the water condenses and collects throughout the compressed air system.
The consequences are often more serious than many operators assume.
Moisture in compressed air can cause corrosion in piping, damage valves and pneumatic cylinders, wash out lubricants or lead to faults in automated production systems. In painting processes it causes surface defects, while in the food or wood industries even small amounts of moisture can impair product quality.
A refrigeration dryer prevents exactly these problems. It cools the compressed air to a pressure dew point of approximately +3 °C. The moisture it contains condenses, is separated and automatically removed from the system. The result is dry compressed air in accordance with ISO 8573-1 Class 4, which protects machines and increases process reliability.
The refrigeration dryer – an often underestimated electricity consumer
Ask production managers about the biggest energy consumers in a compressed air system and the screw compressor is almost always mentioned first. That is basically correct, but another consumer is often underestimated: the refrigeration dryer.
While modern screw compressors automatically adapt their output to the actual air demand or can even switch off completely at low load, many refrigeration dryers work on an entirely different principle.
They generate cold continuously – regardless of how much compressed air is actually needed.
In modern manufacturing companies with frequently changing jobs in particular, this operating principle leads to unnecessarily high energy costs.
Typical situations include:
- tool changes on CNC machines
- material replenishment
- set-up times
- lunch breaks
- shift changes
- production interruptions
- nights and weekends
While compressed air consumption drops significantly during these phases, the refrigeration dryer usually keeps running unchanged.
The result: energy is consumed even though only a fraction of the maximum cooling capacity is needed.
Why conventional refrigeration dryers use energy unnecessarily
A conventional refrigeration dryer works much like a refrigerator. Its refrigeration compressor generates cold continuously to ensure the required pressure dew point.
This concept is technically simple and reliable, but it has one decisive disadvantage: the refrigeration dryer does not know the actual compressed air demand.
Whether production is running at full capacity or only individual machines are operating makes little difference to many units. The refrigeration compressor stays in operation for much of the day.
This problem becomes particularly clear outside actual production hours. Many companies leave their compressed air system under pressure at night or at weekends. This keeps machines ready for operation and the lines available at all times.
The actual air demand is then often limited to small leaks. Nevertheless, the refrigeration dryer often continues to run at almost the same output as during production.
Over a whole year, this unnecessary energy consumption adds up to several thousand operating hours.
This is exactly where conventional, variable speed and cycling refrigeration dryers differ fundamentally.
In the next part, we compare the three technologies and show why the Hankison HDI-E series offers clear advantages, especially when compressed air demand fluctuates strongly.