Sysadvance OXYGEN

Oxygen generators with PSA technology, purity up to 95%

If you buy oxygen in cylinders or as liquid gas, you pay not only for the gas, but also for rental, transport and the effort involved in storage and safety. A Sysadvance oxygen generator produces the oxygen directly on your premises, from compressed air and electricity – permanently available and at predictable costs.

The units are robust and modular in design. They can easily be integrated into an existing compressed air station and supplemented with further units as demand grows.

Purity

85 to 95%

Flow rate

0.9 to 160 Sm³/h

Oxygen pressure

up to 5 bar, more with booster

Why generate your own oxygen?

Depending on consumption, oxygen generated on site costs up to 90% less than purchased oxygen. No more orders, no more cylinder changes and no more supply shortages – and you are independent of gas market prices.

Safety benefits too: instead of storing and transporting high-pressure cylinders or liquid oxygen, the generator produces only as much as you need at the time.

  • Up to 90% lower oxygen costs compared with cylinders or tanks
  • Oxygen around the clock, without orders or cylinder changes
  • Greater safety: no storage or transport of high-pressure cylinders
  • Oxygen pressure up to 5 bar without booster, cylinder filling up to 300 bar possible
  • Oxygen analyser and controller with display as standard
  • Modular and expandable, also available as a container or skid solution

Where on-site oxygen is used

Water and wastewater

Aeration in wastewater treatment plants and oxygen for ozone generation in water treatment.

Fish farming and aquaculture

More oxygen in the water for healthy fish, higher stocking density and better growth, including in recirculating systems.

Glass, metal and stone

Oxygen for burners, welding and plasma cutting, as well as for flame texturing of natural stone surfaces.

Biogas and processes

Desulphurisation in biogas plants, oxidation processes in the chemical industry, and applications in laboratories and veterinary medicine.

How a PSA oxygen generator works

The generator works with two columns filled with a zeolite molecular sieve. As compressed air flows through, the zeolite retains the nitrogen, while the oxygen passes through and is collected in a vessel.

While one column produces oxygen, the other is depressurised and releases the nitrogen again. The two alternate continuously – producing a steady flow of oxygen with up to 95% purity. For more demanding applications, two-stage systems up to 99% are available on request.

As with nitrogen, clean, dry compressed air of class 1:4:1 according to ISO 8573-1 is required upstream, with a refrigeration dryer and filters. We supply the entire chain from a single source and match it to the generator.

Product images

Technical data

Model85% [Sm³/h]90% [Sm³/h]93% [Sm³/h]95% [Sm³/h]
OXYGEN 10C1.261.161.070.94
OXYGEN 252.932.672.071.67
OXYGEN 354.44.03.12.5
OXYGEN 506.56.04.63.8
OXYGEN 709.28.56.55.3
OXYGEN 8011.210.48.06.5
OXYGEN 9013.412.49.57.8
OXYGEN 11017.516.212.410.1
OXYGEN 15025.623.718.214.8
OXYGEN 20036.934.126.221.3
OXYGEN 30051.447.636.529.7
OXYGEN 40061.256.743.535.3
OXYGEN 50078.372.655.745.2
OXYGEN 800109.6101.682.767.2
OXYGEN 1500160.0145.0120.095.0
OXYGEN – oxygen flow rate by purity

Applies to all models:

ProcessPSA with zeolite molecular sieve
Compressed air inlet pressure6.5 bar(g) (basis of the table)
Compressed air quality1:4:1 according to ISO 8573-1, upstream refrigeration dryer with +3 °C pressure dew point
Oxygen pressure dew pointapprox. −40 °C
Oxygen pressureup to 5 bar without booster
ControlDisplay, oxygen analyser, remote start/stop, data logging
OptionsBooster and filling station up to 300 bar, flow measurement, container or skid version
OXYGEN – common data for all models

Flow rates at standard conditions (15 °C, 1,013.25 mbar); purity ± 1%. Other purities and flow rates on request, as are two-stage systems up to 99% purity.

Frequently asked questions

What purity does a PSA oxygen generator deliver?

Between 85 and 95%. That is sufficient for the vast majority of industrial applications such as wastewater, aquaculture, burners or ozone generation. With a second purification stage, up to 99% is possible.

How much will I save compared with cylinders or liquid oxygen?

Depending on your consumption and current gas prices, 30 to 90% of your gas costs. Many systems pay for themselves within one to two years.

When is a VSA generator worthwhile instead of PSA?

For large, steady volumes at low pressure, for example in wastewater treatment plants. The VSA generator needs no compressed air and around half as much energy. For small and medium volumes, PSA is the more economical choice.

What does the generator need on site?

Clean, dry compressed air and a power supply. It is installed indoors or outdoors under cover; larger systems are available ready to connect in a container.

How much maintenance does the generator need?

Above all, the compressed air treatment needs regular maintenance: filters, condensate drains and dryer. In addition, the valves and analyser are checked. Well looked after, the systems run for 15 to 20 years and more.

How is purity monitored?

An oxygen analyser is fitted as standard. Pressure, flow and dew point measurement, data logging and remote monitoring are available as options.

Download

Which generator suits your application?

Purity, volume and pressure determine whether a PSA or a VSA generator is the better fit. We advise you, design the system including the compressed air supply and remain at your side after commissioning.