Sysadvance OXYGEN VSA
Oxygen in large volumes, with half the energy
Where large amounts of oxygen at low pressure are needed around the clock, for example in wastewater treatment plants, fish farms or glassworks, the VSA generator is the most economical solution. It does not work with compressed air; instead, a blower draws in ambient air, and regeneration takes place under vacuum.
The result: around 50% less energy per cubic metre of oxygen than a PSA generator, a longer service life for the adsorbent and less maintenance.
Flow rate
18 to 144 Sm³/h
Purity
up to 93%
Energy consumption
below 0.4 kWh/Nm³
Why VSA?
In the PSA process, most of the energy is consumed by the compressor that supplies the compressed air. The VSA generator does without it: a blower feeds ambient air into the columns at a slight overpressure, and a vacuum pump then draws the nitrogen back out. This halves the power requirement.
The oxygen is available at 500 mbar overpressure. With an additional blower, 2 bar is possible; with a scroll or piston compressor, up to 8 bar.
- Around 50% less energy than PSA: below 0.4 kWh/Nm³ at 90% purity
- Purity up to 93%, pressure dew point below −50 °C
- No compressed air treatment required: intake directly from the surroundings
- Longer adsorbent service life and less maintenance
- Oxygen sensor with output signal for remote monitoring
- On a base frame or in a container, delivered ready to connect
Where VSA oxygen is used
Wastewater treatment plants
Aeration of the biological stage, ozone generation and odour reduction through less hydrogen sulphide in pumping stations.
Biogas plants
Oxygen for biological desulphurisation of biogas.
Aquaculture
Oxygen supply for fish farms with large, steady demand.
Industry
Oxy-fuel combustion in foundries, cement works and glassworks, and bleaching in paper and pulp production.
How a VSA generator works
VSA stands for vacuum swing adsorption. A blower forces ambient air at a maximum of 2,000 mbar (absolute) through one of two columns containing zeolite. The zeolite binds the nitrogen, and the oxygen flows into the product receiver. The column is then evacuated to 200 to 500 mbar (absolute) by a vacuum pump and releases the nitrogen again. The two columns alternate continuously.
Technical data
| Model | Flow rate at 90% [Sm³/h] | Flow rate at 93% [Sm³/h] | Energy consumption at 500 mbar(g)¹ [kWh/m³] | Energy consumption at 8 bar(g)² [kWh/m³] |
|---|---|---|---|---|
| OXYGEN VSA 20 | 22 | 18 | 0.40 | 0.53 |
| OXYGEN VSA 30 | 42 | 30 | 0.40 | 0.53 |
| OXYGEN VSA 60 | 72 | 60 | 0.40 | 0.53 |
| OXYGEN VSA 90 | 108 | 90 | 0.40 | 0.53 |
| OXYGEN VSA 120 | 144 | 120 | 0.40 | 0.53 |
| Process | VSA with zeolite, intake of ambient air |
|---|---|
| Oxygen pressure | 500 mbar(g); 2 bar with blower, up to 8 bar with compressor |
| Oxygen pressure dew point | below −50 °C |
| Power supply | 400 V AC, 50 Hz, three-phase |
| Design | on a base frame or in a container |
¹ Blower, vacuum pump and controller. ² Additionally, compression of the oxygen to 8 bar. Standard conditions 15 °C, 1,013.25 mbar, 40% relative humidity; purity ± 2%, energy consumption and flow rate ± 5%. Other flow rates and pressures up to 300 bar on request.
Frequently asked questions
What is the difference between VSA and PSA?
The PSA generator needs compressed air and regenerates by depressurisation. The VSA generator draws in ambient air with a blower and regenerates under vacuum. This saves around half the energy, but delivers the oxygen at a lower pressure.
From what volume is VSA worthwhile?
Typically from around 20 m³/h in continuous operation. Below that, a PSA generator is usually cheaper to buy.
What purity does the VSA generator achieve?
Up to 93%, designed for 90% with the lowest energy consumption. We clarify higher requirements together with the manufacturer.
Does the VSA generator need compressed air treatment?
No. It draws in air directly from the surroundings, so there is no need for a compressor with dryer and filters.
How is the system delivered?
On a base frame or ready to connect in a container, with compression of the oxygen up to 8 bar on request.
Download

Which generator suits your application?
Whether PSA or VSA is the better fit depends on volume, pressure and operating hours. We calculate both options for you and support you from design through to service.